dicom-series-to-volume

by @nvidiav
4.3(120)

This Skill converts a CT DICOM series folder to a Hounsfield Unit NIfTI volume with affine evidence. It automatically applies rescale slope/intercept and builds orientation/spacing matrices, ideal for medical imaging preprocessing and segmentation pipeline inputs, saving time and reducing manual conversion errors.

dicomniftictmedical-imagingconversionGitHub
Installation
npx skills add https://github.com/nvidia/skills --skill dicom-series-to-volume
compare_arrows

Before / After Comparison

1 组
Before

Without this Skill, developers had to manually run tools like dcm2niix, write scripts to handle Rescale parameters and affine matrices, often taking over 30 minutes and prone to volume deformation due to parameter errors.

After

This Skill performs the conversion in one step, automatically parsing DICOM headers. Each conversion takes about 2 minutes, outputting a standard NIfTI file and validation JSON with reliable quality.

SKILL.md

dicom_series_to_volume

Purpose

  • Used for converting one CT DICOM series folder to a HU NIfTI volume with affine evidence. Not for multi-frame DICOM or clinical use.
  • Use the wrapper exactly as documented; do not replace the upstream entrypoint with a handwritten implementation.
  • Manifest I/O: inputs are dicom_dir; outputs are nifti_volume and result_json.

Instructions

  • Read skill_manifest.yaml before changing arguments, side effects, or validation gates.
  • Run scripts/series_to_volume.py through the documented command below; keep outputs under a caller-provided run directory.
  • If a host agent exposes run_script, use run_script("scripts/series_to_volume.py", args=[...]); otherwise run the Bash/Python command shown below.
  • Check the emitted JSON and the paired dicom_volume_quality_v1 verifier before treating the run as evidence.

Available Scripts

ScriptPurposeArguments
scripts/series_to_volume.pyPrimary entrypoint declared by skill_manifest.yaml.PATH_TO_DICOM_DIR [--output OUT.nii.gz]

Prerequisites

  • Runtime requirements: Python packages listed in runtime.side_effects.pip_packages.
  • Run commands from the repository root unless an existing section below says otherwise.

Limitations

  • Single-series only; multi-series input is rejected at preflight.
  • Multi-frame DICOM (NumberOfFrames > 1 per file) not supported.
  • Compressed transfer syntaxes (JPEG / JPEG2000 / RLE) not supported.
  • No voxel reorientation. The affine is derived from DICOM headers and represented in NIfTI/RAS coordinates; a downstream gate (e.g. expected_axcodes) is expected to assert orientation before this volume is fed to a segmentation model.
  • Not for clinical deployment, autonomous diagnosis, regulatory submission, production inference (use a vetted converter such as dcm2niix for that).

Troubleshooting

ErrorCauseFix
Missing dependency or import errorRuntime package drift from skill_manifest.yaml.Install the packages declared in the manifest or use the documented setup command.
Empty or schema-invalid outputWrong input path, unsupported modality, or upstream failure.Re-run with a known fixture and inspect the wrapper JSON plus stderr.
Validation gate failureOutput violated a declared engineering invariant.Keep the failed evidence pack and use the gate message to repair inputs or wrapper code.

Reads one DICOM series, sorts slices by ImagePositionPatient, applies RescaleSlope and RescaleIntercept, builds an affine from orientation and spacing tags, and writes a .nii.gz plus JSON summary.

python scripts/series_to_volume.py PATH_TO_DICOM_DIR --output PATH_TO_OUT.nii.gz

For a trusted run with the paired verifier:

python -m eval_engine.run_trusted skills/dicom-series-to-volume \
  --fixture PATH_TO_DICOM_DIR \
  --out runs/dicom_series_to_volume_trusted

Key output fields: n_slices, series_instance_uid, output.path, output.shape, output.spacing, output.axcodes, output.affine, hu_range, and runtime.conversion_seconds.

Scope limits: single-series CT only; no multi-frame DICOM, compressed transfer syntax handling, RT structure sets, auto-reorientation, or clinical use.

User Reviews (0)

Write a Review

Effect
Usability
Docs
Compatibility

No reviews yet

Statistics

Installs1.9K
Rating4.3 / 5.0
Version
Updated2026年9月30日
Comparisons1

User Rating

4.3(120)
5
37%
4
43%
3
13%
2
5%
1
2%

Rate this Skill

0.0

Compatible Platforms

🤖claude-code

Timeline

Created2026年7月26日
Last Updated2026年9月30日
🎁 Agent Knowledge Cards
Survey